Anesthesiology and Pain Medicine

Published by: Kowsar

Use of two Endotracheal Tubes to Perform Lung Isolation and One-Lung Ventilation in a Patient With Tracheostomy Stenosis: A Case Report

Mehryar Taghavi Gilani 1 , Mehdi Fathi 1 and Majid Razavi 1 , *
Authors Information
1 Cardiac Anesthesia Research Center, Imam-Reza Hospital, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
Article information
  • Anesthesiology and Pain Medicine: October 01, 2014, 4 (4); e18280
  • Published Online: September 10, 2014
  • Article Type: Case Report
  • Received: February 16, 2014
  • Revised: February 20, 2014
  • Accepted: April 22, 2014
  • DOI: 10.5812/aap.18280

To Cite: Taghavi Gilani M, Fathi M, Razavi M. Use of two Endotracheal Tubes to Perform Lung Isolation and One-Lung Ventilation in a Patient With Tracheostomy Stenosis: A Case Report, Anesth Pain Med. 2014 ; 4(4):e18280. doi: 10.5812/aap.18280.

Abstract
Copyright © 2014, Iranian Society of Regional Anesthesia and Pain Medicine (ISRAPM). This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
1. Introduction
2. Case Presentation
3. Discussion
Acknowledgements
Footnote
References
  • 1. Campos JH. Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial blockers. Curr Opin Anaesthesiol. 2007; 20(1): 27-31[DOI][PubMed]
  • 2. Garcia-Guasch R, Campos JH, Granell M, Pena JJ. [Applications for bronchial blockers in thoracic surgery]. Rev Esp Anestesiol Reanim. 2007; 54(9): 547-55[PubMed]
  • 3. Campos JH. Lung isolation techniques for patients with difficult airway. Curr Opin Anaesthesiol. 2010; 23(1): 12-7[DOI][PubMed]
  • 4. Eun MC, Kyung SB, Il SK, Seung WJ, Young JY, Keun MS, et al. One-Lung Ventilation Using a Fogarty Catheter in a Patient with Tracheostomy after Pharyngectomy and Laryngectomy. Korean J Anesth. 2005; 49(1): 111-3
  • 5. Campos JH, Hallam EA, Ueda K. Lung isolation in the morbidly obese patient: a comparison of a left-sided double-lumen tracheal tube with the Arndt(R) wire-guided blocker. Br J Anaesth. 2012; 109(4): 630-5[DOI][PubMed]
  • 6. Coe VL, Brodsky JB, Mark JB. Double-lumen endobronchial tubes for patients with tracheostomies. Anesth Analg. 1984; 63(9): 882[PubMed]
  • 7. Yaney LL. Double-lumen endotracheal tube for one-lung ventilation through a fresh tracheostomy stoma: a case report. AANA J. 2007; 75(6): 411-5[PubMed]
  • 8. Yang M,, Kim GS,, Sim WS,, Gwak MS,, Hahm TS,, Chung IS. A Study of a Separated Bronchial Blocker. Korean J Anesth. 2001; 40(5): 567-71